Product:
This test suite release is an update based on the specification: "ISO/IEC 10373-7:2019 - "Cards and security devices for personal identification — Test methods — Part 7 Contactless vicinity objects".
The following changes have been made since v1.01:
NEW
- Implementation is compliant to ISO/IEC 10373-7:2019 standard
- Add a dedicated calibration campaign to setup the RF power and the waveforms in transmission
- Add a MS-Word docx report following KEOLABS compliance report
IMPROVMENT
- Group all tests conditions in the same test campaign
- Generate evidences in XDATA format
- Functional tests includes both encoding, data rates and single or double subcarrier selection
Hardware Requirements
This test suite requires the following hardware equipment:
- A ProxiLAB Quest platform
- An ISO Test VCD Assembly
- A 50W RF amplifier model Bowen M2.30.70S
- An Oscilloscope
- Lecroy HDO6034 or HDO6034A with firmware version 9.1.0.3
- Lecroy HDO6034B with firmware version 10.4.0.3
- A RF Probe4
- A 3dB RF attenuator
Software Requirements
This test suite requires the following software from KEOLABS with Quest hardware:
- ProxiLAB 4.53.0
- SCRIPTIS 1.09.2
- RGPA 3.21.1
- Quest 1.09.0
- ProxiLABforQuest 1.07.0
Download Center